General Features:
UL&CSA
GRADE
Rate temperature: 105°C
Rate voltage: 600V
Flame test: VW-1
Material of
insulation: polyvinyl chloride(PVC)gray
Insulation thickness average: 15 mil.
Minimum insulation thickness: 13 mil.
After 7
days air oven at 136°C
Average tensile strength: 1500Ibs/inch
Percent of original: 70% at least
Average elongation: 200%
Percent of original: 65% at least
* Custom
Length Are Available Upon Request
AWG size: 18AWG
Number of strands in each conductor: 7/0.386mm.
Lay of strands in each conductor: 2 inch at least
Cross section area:1300mil.
- ELECTRONIC CHARACTERISTICS:
Spark test: 5000V
Dielectric strength test: Minimum 3KV in 1 minute
Conductor Maximum: Maximum 22 /km
Insulation resistance: Minimum200M -km
Capacity: 38pF/m
Inductance: 1.5uH/m
Impedance: 55
Propagation delay time: 4.0ns/m

Solid Internal wiring of electronic equipment, such as computers and electronic business machines.Also used in power lines.
|
Code No.
|
Number of
Cores
|
Size of
conductor
|
Thickness (mm 0.05)
|
Width (mm)
|
Allowable Error(mm)
|
|
(AWG)
|
Composition (solid/mm)
|
|
HJ18-3
|
3
|
18
|
7/0.386
|
2.0
|
11.88
|
0.40
|
|
HJ18-4
|
4
|
18
|
7/0.386
|
2.0
|
15.84
|
0.40
|
|
HJ18-5
|
5
|
18
|
7/0.386
|
2.0
|
19.80
|
0.40
|
|
HJ18-6
|
6
|
18
|
7/0.386
|
2.0
|
23.76
|
0.40
|
|
HJ18-7
|
7
|
18
|
7/0.386
|
2.0
|
27.72
|
0.40
|
|
HJ18-8
|
8
|
18
|
7/0.386
|
2.0
|
31.68
|
0.40
|
|
HJ18-9
|
9
|
18
|
7/0.386
|
2.0
|
35.64
|
0.40
|
|
HJ18-10
|
10
|
18
|
7/0.386
|
2.0
|
39.60
|
0.40
|
|
HJ18-12
|
12
|
18
|
7/0.386
|
2.0
|
47.52
|
0.40
|
|
HJ18-14
|
14
|
18
|
7/0.386
|
2.0
|
55.44
|
0.40
|
|
HJ18-16
|
16
|
18
|
7/0.386
|
2.0
|
63.36
|
0.40
|
|
HJ18-18
|
18
|
18
|
7/0.386
|
2.0
|
71.28
|
0.40
|
|
HJ18-20
|
20
|
18
|
7/0.386
|
2.0
|
79.20
|
0.40
|
|
HJ18-21
|
21
|
18
|
7/0.386
|
2.0
|
83.16
|
0.50
|
|
HJ18-22
|
22
|
18
|
7/0.386
|
2.0
|
87.12
|
0.50
|
|
HJ18-24
|
24
|
18
|
7/0.386
|
2.0
|
95.04
|
0.50
|

|